Notes on laboratory practice, handling and documentation. Written for people at the bench.

Laboratory Practice

Reconstituting a Lyophilised Peptide Without Spoiling the Batch

Reconstitution looks like the simplest step in the workflow and is one of the easiest places to lose material. A few habits make the difference between a clean solution and a cloudy vial.

Read article

Why Your Powder Weighs Differently Every Time

A balance that repeats perfectly with a calibration weight and drifts with a powder is not faulty. It is telling you about charge.

Read article

Short Spins, Big Difference: Plate Centrifugation in PCR Workflows

A few seconds of centrifugation prevents a class of problems that are otherwise easy to misdiagnose as pipetting error or failed chemistry.

Read article

Benzyl Alcohol in Bacteriostatic Water: Helpful, and Sometimes Wrong

The preservative that makes a multi-dose vial practical is also the reason bacteriostatic water is not interchangeable with plain sterile water.

Read article

Building a Workable Cold Chain for a Small Laboratory

A cold chain is not one freezer. It is the sequence from supplier dispatch to the moment a vial is opened, and it fails at the weakest link.

Read article

Choosing a Vial Size: Matching Quantity to Study Length

Buying the largest vial available is not the economical choice if half of it degrades before you get to it. Quantity should follow the study plan.

Read article
Quality

What an HPLC Purity Figure Actually Tells You

A purity number on a certificate is a summary of one chromatographic run. Understanding what sits behind that number changes how much weight you put on it.

Read article

Storing NAD+ So It Is Still NAD+ When You Need It

Nicotinamide adenine dinucleotide is a reagent that degrades quietly. The failure shows up as an assay that underperforms rather than as a visible change in the vial.

Read article

What Actually Happens to a Peptide Across Freeze-Thaw Cycles

Freezing is supposed to preserve material. Done badly, it is a degradation step that repeats every time the vial comes out of the freezer.

Read article

Batch Documentation: What to Keep, and for How Long

A certificate that cannot be matched to the vial in your hand is a piece of paper. The link is the lot number, and it has to survive the trip from supplier to bench.

Read article
Equipment

Class B or Gravity Displacement: Choosing an Autoclave for a Small Lab

The two cycle types look similar on a specification sheet and behave very differently on wrapped instruments. The choice usually comes down to what you actually put in the chamber.

Read article

Semi-Micro vs Analytical: What 0.1mg Readability Buys You

The gap between a four-place and a five-place balance is not just one more digit. It changes what samples you can weigh and how the weighing has to be set up.

Read article